| Vogue garage conversions choose Kingspan
insulation products for garage conversions.
TR21 Thermaroof insulation for garage conversion flat
roofs
PREMIUM PERFORMANCE
For insulating directly over timber joists we recommend
the use of Kingspan Thermaroof TR31 zero ODP. Incorporating
a 6 mm WBP plywood upper surface and a foil underside,
Kingspan Thermaroof TR31 zero ODP combines decking,
insulation and vapour control layer in a single product.
Suitable for use beneath built–up felt roofing
systems this offers all the benefits of a warm roof
construction whilst being quick and simple to install.
Product details
|
Achieving “U”
values |
|
|
Thickness does not include 6 mm WBP Plywood.
With appropriate waterproofing and chippings.
Based on 3 layers of partially bonded built up felt
with the surface covered in mineral chippings, a Kingspan
Thermaroof TR31 zero ODP board is laid over the timber
joists with a skim coated single layer of 12.5 mm plasterboard
fixed to the underside. For the purpose of these calculations
the standard of workmanship has been assumed good and
therefore the correction factor for air gaps has been
ignored.
Product thickness = insulation thickness + 6 mm ply.
Due to limited lengths of fixings, 96 mm overall depth
of Kingspan Thermaroof TR31 zero ODP is the maximum
practical thickness. In order to achieve 0.22 W/m².K
20 mm Kingspan Thermapitch TP10 zero ODP is required
between rafters. (See page 12 for details of Kingspan
Thermapitch TP10 zero ODP.)
The ?–value quoted is in accordance with the
Harmonised European Standard BS EN 13165 (urethane)
and BS EN 13166 (phenolic) using so called 90/90 principles.
Comparison with alternative products may not be appropriate
unless the same procedures have been followed
Fixing details
Suitable for use over joists at 400 mm and 600 mm centres.
Lay boards, plywood facing upwards with long edges following
joists and with board joints staggered
Insulation thickness 45 to 50mm
Kingspan Thermaroof TR31 zero ODP should be fixed with
suitable galvanised ring shank nails.
These are to be placed at 100 mm centres around the
board edges and at 300 mm centres along any intermediate
supporting timbers.
Insulation over 50mm
Kingspan Thermaroof TR31 zero ODP should be fixed with
low profile oval head screw fixings. These are to be
placed at 200 mm centres around the board edges and
at 300 mm centres along any intermediate supporting
timbers
General
All edges of the board should be supported. The use
of 50 x 50 mm cross–noggins will ensure this along
the boards shorter edges and where boards may be cut
at openings or details.
A wide bead of non–setting gun–grade mastic
sealant, applied along the centre of the joists and
cross–noggins will ensure a continuous vapour
control layer on the foil underside of the boards. The
mastic sealant must be wide enough to accommodate two
board edges butted together see figure 3.
Sheets should be lightly butted (approx. 2 mm gap)
whilst maintaining a 20 mm bearing at edges over supporting
timbers.
Fixings should not be positioned within 10 mm of the
board edges or within 50 mm of the corners.
Care should be taken to keep the decking dry prior to
waterproofing. Always utilise a type 3G felt as the
base layer to a 3 layer felt system.
To avoid cold bridging ensure the wall insulation around
the roof perimeter is carried up 300 mm (min) above
to the underside of the insulated deck.
This creates a warm roof construction therefore ventilation
is not necessary.
Cutting should be carried out using a fine-toothed saw
The insulation products described above are the materials
of choice of Vogue Garage Conversions and are supplied
by - Kingspan Insulation Ltd
|