Vogue garage conversions choose
Kingspan insulation products for garage conversions.
TR21 Thermaroof insulation for garage
conversion flat roofs
PREMIUM PERFORMANCE
For insulating directly over timber joists
we recommend the use of Kingspan Thermaroof TR31 zero ODP.
Incorporating a 6 mm WBP plywood upper surface and a foil underside,
Kingspan Thermaroof TR31 zero ODP combines decking, insulation and
vapour control layer in a single product. Suitable for use beneath
built–up felt roofing systems this offers all the benefits of a
warm roof construction whilst being quick and simple to install.
|
Product details
|
Achieving
“U” values
|
|
|
|
Thickness does not include 6 mm WBP Plywood.
With appropriate waterproofing and chippings.
Based on 3 layers of partially bonded built
up felt with the surface covered in mineral chippings, a Kingspan
Thermaroof TR31 zero ODP board is laid over the timber joists with a
skim coated single layer of 12.5 mm plasterboard fixed to the
underside. For the purpose of these calculations the standard of
workmanship has been assumed good and therefore the correction factor
for air gaps has been ignored.
Product thickness = insulation thickness + 6
mm ply.
Due to limited lengths of fixings, 96 mm
overall depth of Kingspan Thermaroof TR31 zero ODP is the maximum
practical thickness. In order to achieve 0.22 W/m².K 20 mm
Kingspan Thermapitch TP10 zero ODP is required between rafters. (See
page 12 for details of Kingspan Thermapitch TP10 zero ODP.)
The ?–value quoted is in accordance
with the Harmonised European Standard BS EN 13165 (urethane) and BS EN
13166 (phenolic) using so called 90/90 principles. Comparison with
alternative products may not be appropriate unless the same procedures
have been followed
Fixing details
Suitable for use over joists at 400 mm and 600 mm centres.
Lay boards, plywood facing upwards with long edges following joists and
with board joints staggered
Insulation thickness 45 to 50mm
Kingspan Thermaroof TR31 zero ODP should be fixed with suitable
galvanised ring shank nails.
These are to be placed at 100 mm centres around the board edges and at
300 mm centres along any intermediate supporting timbers.
Insulation over 50mm
Kingspan Thermaroof TR31 zero ODP should be fixed with low profile oval
head screw fixings. These are to be placed at 200 mm centres around the
board edges and at 300 mm centres along any intermediate supporting
timbers
General
All edges of the board should be supported. The use of 50 x 50 mm
cross–noggins will ensure this along the boards shorter edges and
where boards may be cut at openings or details.
A wide bead of non–setting gun–grade mastic sealant,
applied along the centre of the joists and cross–noggins will
ensure a continuous vapour control layer on the foil underside of the
boards. The mastic sealant must be wide enough to accommodate two board
edges butted together see figure 3.
Sheets should be lightly butted (approx. 2
mm gap) whilst maintaining a 20 mm bearing at edges over supporting
timbers.
Fixings should not be positioned within 10 mm of the board edges or
within 50 mm of the corners.
Care should be taken to keep the decking dry prior to waterproofing.
Always utilise a type 3G felt as the base layer to a 3 layer felt
system.
To avoid cold bridging ensure the wall insulation around the roof
perimeter is carried up 300 mm (min) above to the underside of the
insulated deck.
This creates a warm roof construction therefore ventilation is not
necessary.
Cutting should be carried out using a fine-toothed saw
The insulation products described above are
the materials of choice of Vogue Garage Conversions and are supplied by
- Kingspan Insulation Ltd
|